A) Disconnect the switch sensor connector. Ground the connector terminal.
b) turn on the ignition: the indicator lamp should be on.
2. Checking the operation of the sensor-switch.
A) check for continuity between the sensor lead and ground when the engine is not running.
b) check for continuity between the sensor lead and ground with the engine running.
Note: The sensor contacts open at 0.2 bar oil pressure.