Checking the relay (4A-FE and 7A-FE)
1. Checking the relay.
- a) Using an ohmmeter, check for continuity between terminals "3" and "4" (type A) or "3" and "4" (type B).
- b) Using an ohmmeter, check for continuity between terminals "1" and "2" (type A) or "3" and "5" (type B). If the continuity is not as stated above, replace the relay.
4A-FE (types A and B) and 7A-FE (type A) |
4A-FE and 7A-FE (starter type A) |
4A-FE (starter type B)
2. Checking the operation of the relay.
- a) Apply battery voltage to terminals "3" and "4" (type A) or "1" and "2" (type B)
- b) Using an ohmmeter, check for continuity between terminals "1" and "2" (type A) or "3" and "5" (type B). If the continuity is not as stated above, replace the relay.
Checking the relay (3S-FE, 4S-FE, 2C, 2C-T)

The official source is on the portal (toyotaman.ru)
1. Remove the relay box cover.
2. Remove the starter relay.
3. Checking the relay.
- a) Using an ohmmeter, check for continuity between terminals "1" and "2".
- b) Using an ohmmeter, make sure there is no conductivity between terminals "3" and "5".
If the conductivity does not match the above, replace the relay.

4. Checking the operation of the relay.
- a) Connect the battery voltage to terminals "1" and "2".
- b) Using an ohmmeter, check for continuity between terminals "3" and "5".
If the conductivity does not match the above, replace the relay.
5. Reinstall the relay.
6. Install the relay box cover.