2. If the engine can be started in other positions, then adjust the engine start inhibit switch.
- A) Loosen the bolts of the start switch in neutral position and set the selector to the position "N".
- b) Align the groove and the neutral base line.
- V) While holding the parts in this position, tighten the bolts. Tightening torque 5.4 Nm
A241L | A240E, A241E. A132L |
A245E | Models since 1996 |
3.A132L. Check the start inhibit switch.
Check up conductivity between conclusions of a socket of the switch of prohibition of start of the engine in each position of the selector. If the conductivity is not as indicated in the table, then replace the start inhibit switch.
Range | conclusions | State |
R | 2-3 6-1 | Conductivity |
R | 6-5 | Conductivity |
N | 2-3 6-7 | Conductivity |
D | 6-8 | Conductivity |
2 | 6-9 | Conductivity |
L | 6-4 | Conductivity |