Removal and installation of the pump of a cooling liquid (KZ series).
1 - pulley,
2 - coolant pump,
3 - gasket.
1. Drain the coolant.
2. Remove the accessory drive belt.
3. Remove the coolant pump pulley.
- Tightening torque - 11.5 Nm
4. Remove the coolant pump.
A) Turn away 3 bolts, 2 nuts and remove the pump of a cooling liquid.
Torque:
- bolt - 9 Nm
- nut - 9 Nm
b) Remove the gasket.
Installation is carried out in the reverse order of removal.