1. Checking the reclosing switch.
Turn the ignition switch to position "LOCK" and check the continuity between the terminals "3" And "8" connector.
- Switch in position "NORMAL" - no conduction
- Switch in position "PUSH" - there is conductivity
2. Checking the solenoid valve for blocking the key in the ignition lock.
Connect the positive battery terminal to the terminal "6" connector, and negative - to the output "7" and check that the ignition switch moves from the position "LOCK" into position "ACC".
3. Checking the ignition coil. Check for continuity between terminals "2" And "5" connector.
4. Checking the sensor for the presence of a key in the ignition lock.
Turn the ignition switch to position "LOCK" and check the continuity between the terminals "1" And "4" connector.
- The key is not inserted into the ignition - no conductivity
- The key is inserted into the ignition - there is conductivity
Table. System Diagnostic Trouble Codes "KEY FREE".