2. Install a new gasket and tighten the drain plug.
3. Fill with fresh fluid through the filler tube to the lower range mark "COLD" ("WITH", cold) on the probe.
Working fluid:
- EJ-DE - DEXRON III or equivalent
- KZ-VE, K3-VE2 - Type T-IV or equivalent
The volume of the filled liquid:
IN "dry" gearbox:
- EJ-DE - 4.0 L
- KZ-VE, K3-VE2 - 5.0 l
When replacing:
- EJ-DE - 1.7 L KZ-VE
- K3-VE2 - 1.9 L
4. Start the engine at idle and move the selector to all positions from "R" before "L" and back to position "R".
5. While the engine is running at idle, check the fluid level. If necessary, add fluid to the level "COLD" ("WITH") on the probe.
6. Check fluid level at normal operating temperature of 70-80°C and top up if required.
Note: Do not overfill above the set level.