Replacement
1. Locate the motor connector on the main harness along the wire and
disconnect the connector.
2. Check the resistance between terminals 2 and 3 of the connector. The resistance should be 0.3–100 ohms. Otherwise, replace the motor.
3. Check insulation resistance (between terminals 2 and 3 and ground), which should be at least 0.5 ohm. Otherwise, replace the motor.
4. Disconnect the breather hose and motor connector.
5. Turn away bolts and remove the electric motor.
6. Installation is carried out in the reverse order.