Disassembly
1. Remove the distributor cap without removing the high voltage wires.
2. Remove the distributor rotor.
3. Remove the protective cover (dust deflector) ignition coils.
4. Remove the ignition coil.
A) Turn away two nuts and disconnect wires from conclusions of the coil of ignition.
b) Loosen the four screws and remove the ignition coil and gasket.
5. Disconnect the connecting wire of the distributor.
6. Remove the connector bracket.
Examination
(See, section "Checking distributors after disassembly").
Assembly
1. Install the connector bracket.
Align the protrusion on the distributor body with the groove of the bracket and secure the bracket with a screw.
2. Install the connecting cable of the distributor.
3. Install the ignition coil.
A) Install the gasket and secure the ignition coil with four screws.
b) Attach the three wires to the ignition coil terminals with two nuts as shown.
Attention: when connecting the wires to the ignition coil, insert them into the locking grooves of the ignition coil cover and make sure that the wires do not touch the ignition timing sensor rotor or the distributor housing.
4. Install the protective cover (dust deflector) ignition coils and gasket.
5. Install the distributor rotor.
6. Install the distributor cover with high voltage wires, securing it with three bolts along with the gasket.
7. Install the sealing ring on the guide of the distributor housing, having previously applied a layer of engine oil to the ring.