Removing
Disconnect the mass air flow meter connector.
Pic. 2.564. mass air flow meter
Remove 2 bolts, then remove mass air flow meter (pic. 2.564).
Installation
Install the mass air flow meter and secure it with 2 bolts.
Note. During installation, be careful not to damage or pinch the O-ring.
Connect the mass air flow meter connector.
Connect the negative terminal to the battery terminal.
Tightening torque: 5.4 Nm.