Air conditioning control panel. 1 - blower speed control, 2 - temperature control lever, 3 - recirculation control lever, 4 - air flow control lever.
Checking the fan switch
Check for continuity between the switch connector terminals. Replace the switch if the conductivity differs from the table.
Checking the air conditioning control levers
Checking the operation of the control levers
Make sure that there are no jamming or bending of the levers.
Throttle cable adjustment
1. Adjust the recirculation control cable.
A) Set the damper and control lever to the position "RECIRC" (recycling).
b) Install the cable and fix the clamp.
2. Adjust the air mixing control cable.
A) Set the mixing damper and control lever to the position "COOL".
b) Install the cable and fix the clamp.
3. Adjust the air distribution flap control cable.
A) Set the lever and damper to position "DEF".
b) Install the control cable and fix the clamp.
4. Adjust the heater tap control cable.
A) Set the damper and control lever to the position "COOL".
b) Install the control cable and fix the clamp.