Note: Below are the correct waveforms for various motors.
№10-20-Е1 (5A-FE, 4S-FE)
- Division value: X - 20 ms, Y - 20 V.
- Mode: idle.
№10-20-Е1 (4A-FE, 3S-FE)
- Division value: X - 20 ms, Y - 20 V.
- Mode: idle.
№10-40-Е1 (4A-FE, 5A-FE, 7A-FE since 1994)
- Division value: X - 20 ms, Y - 20 V.
- Mode: idle.
IGT, IGT-E1 (5A-FE, manual transmission)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.
IGT, IGT-E1 (5A-FE, automatic transmission)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.
IGT, IGT-E1 (4A-FE, 7A-FE)
- Division value: X - 10 ms, Y - 2 V.
- Mode: idle.
IGT, IGT-E1 (3S-FE, 7S-FE)
- Division value: X - 10 ms, Y - 2 V.
- Mode: idle.
NE+ - NE- (5A-FE, 4S-FE)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.
G1, G2, NE -G- (4A-FE)
- Division value: X - 50 ms, Y - 5 V.
- Mode: idle.
G+, NE+ -G- (NE-) (3S-FE since 1992)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.
G+ -G-, NE+ -NE- (3S-FE since 1994)
- Division value: X - 50 ms, Y - 2 V.
- Mode: idle.
G+ -G-, NE+ -NE- (4A-FE, 7A-FE since 1994)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.
RSC, RSO-E1 (4A-FE, 5A-FE since 1992), ISCC, ISCO-E1 (3S-FE, 4S-FE)
- Division value: X - 1 ms, Y - 5 V.
- Mode: idle, air conditioning on
RSC, RSO-E1 (4A-FE, 5A-FE since 1992), ISCC, ISCO-E1 (3S-FE, 4S-FE)
- Division value: X - 1 ms, Y - 5 V.
- Mode: idle, air conditioning on
RSC, RSO-E1 (4A-FE, 5A-FE since 1994)
- Division value: X - 1 ms, Y - 5 V.
- Mode: idle, air conditioning off
RSC, RSO-E1 (4A-FE, 5A-FE, 7A-FE since 1994)
- Division value: X - 1 ms, Y - 5 V.
- Mode: idle, air conditioning on
OX-E1 (4A-FE, 5A-FE, 7A-FE, 3S-FE, 4S-FE)
- Division value: X - 500 ms, Y - 0.2 V.
- Mode: rotation speed 2500 rpm
KNK-E1 (4A-FE, 5A-FE, 3S-FE, 4S-FE since 1992)
- Division value: X - 1 ms, Y - 1 V.
- Mode: rotation speed 4000 rpm
KNK-E1 (4A-FE, 5A-FE, 7A-FE, 3S-FE since 1994)
- Division value: X - 1 ms, Y - 0.5 V.
- Mode: rotation speed 4000 rpm
SPD, SP1-E1 (4A-FE, 5A-FE, 7A-FE)
- Division value: X - 20 ms, Y - 5 V.
- Mode: speed 20 km/h
SP1-E1 (3S-FE, 4S-FE)
- Division value: X - 10 ms, Y - 0.5 V.
- Mode: speed 60 km/h
CP1-E1 (4A-FE, 7A-FE)
- Division value: X - 50 ms, Y - 0.5 V.
- Mode: idle
EGR1-4-E1 (4A-FE, automatic transmission)
- Division value: X - 50 ms, Y - 2 V.
- Mode: cranking by starter
VSV-E1 (5A-FE since 1992), EPV-E1 (4A-FE since 1992)
- Division value: X - 100 ms, Y - 5 V.
- Mode: coolant temperature 35°C
EVP-E1 (4A-FE since 1994)
- Division value: X - 100 ms, Y - 5 V.
- Mode: coolant temperature 35°C
EVP-E1 (7A-FE since 1994)
- Division value: X - 100 ms, Y - 5 V.
- Mode: coolant temperature 35°C