Contents: №10-20-E1 (5A-FE, 4S-FE) ↓ №10-20-E1 (4A-FE, 3S-FE) ↓ №10-40-E1 (4A-FE, 5A-FE, 7A-FE since…↓ IGT, IGT-E1 (5A-FE, manual…↓ IGT, IGT-E1 (5A-FE, automatic…↓ IGT, IGT-E1 (4A-FE, 7A-FE) ↓ IGT, IGT-E1 (3S-FE, 7S-FE) ↓ NE+ - NE- (5A-FE, 4S-FE) ↓ G1, G2, NE - G- (4A-FE) ↓ G+, NE+ -G-(NE-) (3S-FE since 1992) ↓ G+ - G-, NE+ - NE- (3S-FE since 1994) ↓ G+ - G-, NE+ - NE- (4A-FE, 7A-FE…↓ RSC, RSO-E1 (4A-FE, 5A-FE since…↓ RSC, RSO-E1 (4A-FE, 5A-FE since…↓ RSC, RSO-E1 (4A-FE, 5A-FE since 1994) ↓ RSC, RSO-E1 (4A-FE, 5A-FE, 7A-FE…↓ OX-E1 (4A-FE, 5A-FE, 7A-FE, 3S-FE,…↓ KNK-E1 (4A-FE, 5A-FE, 3S-FE, 4S-FE…↓ KNK-E1 (4A-FE, 5A-FE, 7A-FE, 3S-FE…↓ SPD, SP1-E1 (4A-FE, 5A-FE, 7A-FE) ↓ SP1-E1 (3S-FE, 4S-FE) ↓ CP1-E1 (4A-FE, 7A-FE) ↓ EGR1-4-E1 (4A-FE, automatic…↓ VSV-E1 (5A-FE since 1992), EPV-E1…↓ EVP-E1 (4A-FE since 1994) ↓ EVP-E1 (7A-FE since 1994) ↓
Note: Below are the correct waveforms for different engines.
№10-20-E1 (5A-FE, 4S-FE)
- Division value: X - 20 ms, Y - 20 V.
- Mode: idle.

№10-20-E1 (4A-FE, 3S-FE)
- Division value: X - 20 ms, Y - 20 V.
- Mode: idle.

№10-40-E1 (4A-FE, 5A-FE, 7A-FE since 1994)
- Division value: X - 20 ms, Y - 20 V.
- Mode: idle.

IGT, IGT-E1 (5A-FE, manual transmission)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.

IGT, IGT-E1 (5A-FE, automatic transmission)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.

IGT, IGT-E1 (4A-FE, 7A-FE)
- Division value: X - 10 ms, Y - 2 V.
- Mode: idle.

IGT, IGT-E1 (3S-FE, 7S-FE)
- Division value: X - 10 ms, Y - 2 V.
- Mode: idle.

(The material was taken from a resource www.ToyotaMan.ru)
NE+ - NE- (5A-FE, 4S-FE)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.

G1, G2, NE - G- (4A-FE)
- Division value: X - 50 ms, Y - 5 V.
- Mode: idle.

G+, NE+ -G-(NE-) (3S-FE since 1992)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.

G+ - G-, NE+ - NE- (3S-FE since 1994)
- Division value: X - 50 ms, Y - 2 V.
- Mode: idle.

G+ - G-, NE+ - NE- (4A-FE, 7A-FE since 1994)
- Division value: X - 20 ms, Y - 2 V.
- Mode: idle.

RSC, RSO-E1 (4A-FE, 5A-FE since 1992), ISCC, ISCO-E1 (3S-FE, 4S-FE)
- Division value: X - 1 ms, Y - 5 V.
- Mode: idle, air conditioning on

RSC, RSO-E1 (4A-FE, 5A-FE since 1992), ISCC, ISCO-E1 (3S-FE, 4S-FE)
- Division value: X - 1 ms, Y - 5 V.
- Mode: idle, air conditioning on

RSC, RSO-E1 (4A-FE, 5A-FE since 1994)
- Division value: X - 1 ms, Y - 5 V.
- Mode: idle, air conditioning off

RSC, RSO-E1 (4A-FE, 5A-FE, 7A-FE since 1994)
- Division value: X - 1 ms, Y - 5 V.
- Mode: idle, air conditioning on

OX-E1 (4A-FE, 5A-FE, 7A-FE, 3S-FE, 4S-FE)
- Division value: X - 500 ms, Y - 0.2 V.
- Mode: rotation speed 2500 rpm

KNK-E1 (4A-FE, 5A-FE, 3S-FE, 4S-FE since 1992)
- Division value: X - 1 ms, Y - 1 V.
- Mode: rotation speed 4000 rpm

KNK-E1 (4A-FE, 5A-FE, 7A-FE, 3S-FE since 1994)
- Division value: X - 1 ms, Y - 0.5 V.
- Mode: rotation speed 4000 rpm

SPD, SP1-E1 (4A-FE, 5A-FE, 7A-FE)
- Division value: X - 20 ms, Y - 5 V.
- Mode: speed 20 km/h
![]() | ![]() |
SP1-E1 (3S-FE, 4S-FE)
- Division value: X - 10 ms, Y - 0.5 V.
- Mode: speed 60 km/h

CP1-E1 (4A-FE, 7A-FE)
- Division value: X - 50 ms, Y - 0.5 V.
- Mode: idle

EGR1-4-E1 (4A-FE, automatic transmission)
- Division value: X - 50 ms, Y - 2 V.
- Mode: cranking with starter

VSV-E1 (5A-FE since 1992), EPV-E1 (4A-FE since 1992)
- Division value: X - 100 ms, Y - 5 V.
- Mode: coolant temperature 35°C

EVP-E1 (4A-FE since 1994)
- Division value: X - 100 ms, Y - 5 V.
- Mode: coolant temperature 35°C

EVP-E1 (7A-FE since 1994)
- Division value: X - 100 ms, Y - 5 V.
- Mode: coolant temperature 35°C