Pic. 2.344. Measurement of crankshaft runout
Place the crankshaft on the prisms. Using a dial indicator, check the runout of the crankshaft on the central main journal (pic. 2.344).
The maximum runout is 0.06 mm.
If the runout is greater than the maximum allowable, replace the crankshaft.